« back

INCUCELL V - Optional equipment – Comfort line

(please specify at ordering)

Door with a window and inner lighting (except for 22-L volume)
Serves to control the activity inside the chamber without the necessity of the unit door opening. The door has a three-layer heat-resistant window and heat-resistant bulbs. The lighting switch is located on the door.
.

Access ports Ø 25, 50,100 mm (Ø 100 mm not available in 22-L volume)
The diameter, number, and location of the access ports is optional. The metal access ports are closed from the outer side by a special plastic plug enabling cables passing through from the outer space into the chamber.
.

Door lockDoor lock
Mechanical lock is situated on the upper front surface of the door near the closing mechanism. It serves for the unit opening prevention by an unauthorized person.
.

Left hinged doorLeft hinged door (except for 22-L volume)
The door is a model with mirror symmetry to the right hinged door.
.

separate PT 100 sensor
An additional freely movable sensor inside the chamber, by means of which the temperature inside the chamber or in the material can be measured. The sensor cables are connected to a connector located in the rear part of the unit.
.

WarmCommSpecial software WarmComm 3.0 B
The software is intended for recording the temperature regulation course in the temperature cabinets. The data acquired during the regulation are displayed in form of a graph (where the horizontal and vertical axis shows the time and acquired data, respectively). The program allows regulation monitoring in real time, saving the regulation course to a file on a disc, and viewing the formerly created files. The WarmComm 3.0 Basic software allows data monitoring of more than 10 connected units.
.

komunikační software WarmCommSpecial software WarmComm 3.0 Professional or WarmComm 3.0 F
The software is intended for recording the temperature regulation course in the temperature cabinets. The data acquired during the regulation are displayed in form of a graph (where the horizontal and vertical axis shows the time and acquired data, respectively). The program allows the regulation monitoring in real time, saving the regulation course to a file on a disc, and viewing the formerly created files.
- The extended version of the WarmComm 3.0 Professional software allows monitoring of the unit data and controlling the unit.
- The full version of the WarmComm 3.0 F software meets the requirements of FDA 21 CFR Part 11. Optional cable length: 5, 10, and 15 m.
.

Stainless steel unit jacket AISI 304
High design quality and long service life of the unit
.

Extension of the working temperature range from 5°C up to 99.9°C
In case higher working temperature than 70°C is required, we offer a model with working temperature up to 99.9 °C.
.

Time-programmable inner waterproof socket (4 pins)
Allows connection of suitable equipment (shaking machine, mixer) placed in the unit chamber.
.

Arrangement against drying of cultivating media and tissue cultures
This mechanical and program adjustment inlcudes an increased chamber tightness, air flap valve blocking, and placement of a humidity tray in the unit.
.

HEPA filter (air filter incorporation) - class S
The filter filters and cleans inlet air from mechanical and biological impurities. HEPA filter is available either in a standard or pressure version. The pressure HEPA filter is equipped with an external fan which presses the ambient air through the HEPA filter to the chamber, thus ensuring about 20 Pa overpressure in the chamber as compared to the unit surroundings. The air filter is a part of optional accessories; it is installed in case of the unit cooling by forced air flow. Filter class: S (DIN 24 184); EU 12 (EUROVENT); H13 (EN 1822).
.

BMS relay alarm contact
Allows remote control of the unit operation. It is connected to a connector in the rear leg of the unit (24 V/1A).
.

High-temperature decontamination 180 °C (except for 404 and 707 liters)
The model is intended for potential microbiological contamination of the chamber. The safety thermostat can be reset by means of a special program installed e.g. on a chip card and subsequently, the limiting temperature and time can be adjusted in the Decontamination program.
.