Menu Hledej +420 545 537 111 mail@bmt.cz
Close

INCUCELL 707 - ECO line

Product images are for illustrative purposes only and may differ from the actual product.
  • natural, accurate - laboratory incubator
  • chamber volume 707 litres
  • temperature range from 5°C above ambient to 100°C
  • characterized by noiseless operation and fine air flow in the usable space
  • high operation comfort, precise temperature control and short chamber temperature equalization times after the door opening
  • high-quality and safe drying, heating and tempering of common laboratory materials in laboratory and industrial areas, suitable for safe processing of microbiological cultures
  • standard version with microprocessor control system Fuzzy logic, controls placed on a foil keyboard, process information displayed on LED display
  • wide selection of optional equipment and accessories
  • output for connecting a printer or PC
  • possibility of validation (IQ, OQ)
I am interested in INCUCELL 707 - ECO line
Technical parameters

Interior of stainless steel material No. 1.4301

volume 707 l
depth 520 mm
width 940 mm
height 1410 mm

Tray

standard equipment 2 pcs
storage area (w × d) 920 × 485 mm
racks 19 max. number
distance between guide rails 70 mm

Maximal weight of the load*)

inside the oven 130 kg/oven
per tray 50 kg/tray

Door

2 pcs

External dimensions (including door and handle)

depth 790 mm
diameter of the air branch outer / inner 52/49 mm
width 1160 mm
1910 (K)

Package dimensions (three layers carton)

depth 860 mm
width 1230 mm
depth 2085 mm

Weight

brut 240 kg
nett 215 kg

Working temperature (beginning of the regulation)

from 5 °C above ambient temp. to: 100 °C

Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door

time variation cca (±) <=0,2 °C
space deviation cca (±) < 1,5 °C

Time required to reach 37 °C with closed air flap and voltage 230 V

59 min

Heat emission at 37 °C

85 W

Air exchange speed at 37 °C

5 per hour

Electricity - mains 50/60 Hz

max. power 0,9 kW
nominal voltage 230 V
current 3,9 A
power by stand by 5 W

*) Approx. 50 % of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber. Note: All technical data are related to 22 °C ambient temperature and +-10 % voltage swing (if not specified).

Changes in the design and make reserved.
The values may differ depending on specific charge and media parameters.
Optional equipment Downloads

Are you interested in INCUCELL 707 - ECO line?

Call us, visit us or fill in the contact form and we will reply by the next working day.

Call Us
+420 545 537 111 Monday - Friday 8.00 am to 4.00 pm
We are out of office
Visit Us
BMT Medical Technology s.r.o. Cejl 157/50, Zábrdovice, 602 00 Brno View a Route on the map

Please fill in the non-binding inquiry




I am Interested in